PYXIS Error Mask Register (ERR_MASK)
Address: 87.4000.8240
The ERR MASK is used to disable the logging and reporting of errors. On power-up, the default is for error logging to be disabled (ERR_MASK = 0). For each bit, a zero (0) disables the logging/reporting of that error, a one (1) enables the corresponding error logging and reporting.
Reserved<31:12>RO N/A
IOA_
TIMEOUT
<11>RW Disable/enable error logging/reporting for I/O timeout errors.
Reserved<10>RO N/A
PA_PTE_INV<9>RW Disable/enable error logging/reporting for invalid PTE errors.
RCVD
_TAR_ABT
<8>RW Disable/enable error logging/reporting for logging/reporting for PCI Target Abort errors.
RCVD
_MAS_ABT
<7>RW Disable/enable error logging/reporting for PCI Master Abort Errors.
PCI_ADDR_PE<6>RW Disable/enable error logging/reporting for PCI Address Parity errors.
PCI_PERR<5>RW Disable/enable error logging/reporting for PCI Data Parity errors.
PCI_SERR<4>RW Disable/enable error logging/reporting for PCI SERR errors.
MEM_NEM<3>RW Disable/enable error logging/reporting for Non-Existent Memory access errors.
CPU_PE<2>RW Disable/enable error logging/reporting for CPU Parity errors
UN_COR_ERR<1>RW Disable/enable error logging/reporting for uncorrectable ECC errors.
COR_ERR<0>RW Disable/enable error logging/reporting for correctable ECC errors.